Inverter- Reliability Test
Inverter- reliability test also known as voltage converter, its function is to convert DC low voltage into AC high voltage, some electronic equipment must be driven by AC power, but we provide is DC power, at this time you must use the Inverter, direct current into alternating current to drive the electronic parts. Inverter- reliability test also known as voltage converter, its function is to convert DC low voltage into AC high voltage, some electronic equipment must be driven by AC power, but we provide is DC power, at this time you must use the Inverter, direct current into alternating current to drive the electronic parts.
Relevant test conditions:
Item |
temperature |
time |
other |
Initial test at normal temperature |
25 ℃ |
TIME≥2 hours |
- |
Low temperature initial test |
0 ℃ or -5 °C |
TIME≥2 hours |
- |
High temperature initial test |
60℃ |
TIME≥2 hours |
- |
High temperature and high humidity test |
40℃/95%RH |
240 hours |
- |
High temperature storage test |
70℃ |
TIME≥96 hours or 240 hours |
- |
Low temperature storage test -1 |
-20°C |
TIME≥96 hours |
- |
Low temperature storage test -2 |
-40℃ |
240 hours |
- |
High temperature and high humidity storage test |
40℃/90%RH |
TIME≥96 hours |
- |
Temperature cycle test |
-20℃~ 70℃ |
5 cycle |
Room temperature ↓-20 ℃(4 hours)↓ Room temperature (90%RH.4 hours)↓70°C(4 hours)↓ Room temperature (4 hours) |
High temperature load test |
55 ℃ |
equivalent load, 1,000 hours |
- |
Life test |
40°C |
MTBF≥40000 hours |
- |
on/off test (power cycle) |
- |
- |
1min:on, 1min:off, 5,000 cycles using equivalent load |
Vibration test |
- |
- |
Acceleration 3q, frequency 10~55HZ, X, Y, Z three directions 10 minutes each, a total of 30 minutes |
Impact test |
- |
- |
Acceleration of 80g, 10 ms each time, Three times in X, Y, Z directions |