banner
Home

Constant Temperature Test Machine

Constant Temperature Test Machine

  • Information Communication Environment Test Solution Information Communication Environment Test Solution
    Dec 09, 2024
    Information Communication Environment Test Solution The statistical analysis shows that the failure of electronic components accounts for 50% of the failure of electronic complete machine, and the reliability detection technology still faces many challenges. Industry Test object Use Technology Solution IT Communication Transmission switching equipment Inspect High temperature placement test High and low temperature (&humidity) test chamber Aging test High and low temperature (&humidity) test chamber Evaluate Thermal cycling test High and low temperature (&humidity) test chamber Tellcordia test High and low temperature (&humidity) test chamber Thermal cycling test   Rapid temperature (&humidity)change test chamber   Mobile communication terminal Inspect Finished operation test High and low temperature (&humidity) test chamber Finished operation test   Rapid temperature (&humidity)change test chamber   Evaluate Temperature and humidity test High and low temperature (&humidity) test chamber Computer Inspect Finished product screening   Rapid temperature (&humidity)change test chamber   High temperature placement test High and low temperature (&humidity) test chamber Aging test High and low temperature (&humidity) test chamber External computer storage device Inspect Component screening High and low temperature (&humidity) test chamber Component screening   Rapid temperature (&humidity)change test chamber   Evaluate Ensure operation test within temperature and humidity range High and low temperature (&humidity) test chamber Ensure operation test within temperature and humidity range   Rapid temperature (&humidity)change test chamber  
    Read More
  • Lab Companion-Rapid Temperature Cycling Test Chamber Lab Companion-Rapid Temperature Cycling Test Chamber
    Nov 13, 2024
    Lab Companion-Rapid Temperature Cycling Test Chamber Introduction of Lab Companion With over 20 years of experience, Lab Companion is a world class manufacturer of environmental chambers and an accomplished supplier of turn-key test systems and equipment.  All our chambers build on Lab Companion’s reputation for long life and exceptional reliability.  With a scope of design, manufacture and service, Lab Companion has established a quality management system that complies with the International Quality System Standard ISO 9001:2008.  Lab Companion’s equipment calibration program is accredited to the International Standard ISO 17025 and the American National Standard ANSI/NCSL-Z-540-1 by A2LA.  A2LA is a full member and signatory of the International Laboratory Accreditation Cooperation (ILAC), the Asia Pacific Laboratory Accreditation (APLAC) and the European Cooperation for Accreditation (EA).  Lab Companion’s SE-Series Environmental Test Chambers offer a significantly enhanced airflow system, which provides better gradients and improved product temperature change rates.  These chambers utilize Thermotron’s flagship 8800 Programmer/Controller featuring a high resolution 12.1” flat panel display with touch screen user interface, expanded capabilities to graph, data log, edit, access on-screen help, and long term hard drive data storage. Not only do we offer the highest quality products, we also provide ongoing support designed to keep you up and running long after the initial sale.  We provide factory direct local service with an extensive inventory of the parts you might need.  Performance Temperature range: -70°C to +180°C Performance: With 23 Kg aluminum load (IEC60068-3-5), the rising rate from +85°C to -40°C is 15℃/min; the cooling rate from -40°C to +85°C is15℃/min too. Temperature control:± 1°C Dry bulb temperatures from control point after stabilization at the control sensor Performance is based on an ambient condition of 75°F (23.9°C) and 50% RH Cooling/Heating Performance based on measurement at the control sensor in the supply air stream Constructure Interior Nonmagnetic Series 300 stainless steel with a high nickel content Internal seams heliarc welded for hermetic sealing of the liner Corners and seams designed to allow for expansion and contraction under the temperature extremes encountered Condensate drain located in the liner floor and under the conditioning plenum Chamber base is fully welded “Ultra-Lite” non-settling fiberglass insulation One adjustable interior stainless steel shelf is standard Exterior Die-formed treated sheet steel Metal access covers provided for easy opening doors to electrical components Finish water-based, air dry lacquer, sprayed over a cleaned and primed surface Easy lift-off hinged access doors for servicing the refrigeration system One 12.5 cm diameter access port with interior weld and removable insulating plug mounted in right hand side wall accessories on hinged door for easy access Features Chamber Operation clearly displays helpful run-time information Graphing Screen offers expanded capabilities, enhanced programming and reporting System Status displays crucial refrigeration system parameters Program Entry makes it easy to load, view and edit profiles Set Up quick-step wizards make profile entry easy Pop-up Refrigeration Charts for handy reference Therm-Alarm® provides over & under temperature alarm protection Activity Log Screen provides comprehensive equipment history Web Server allows internet access to equipment via Ethernet User-Friendly Pop-up Key Pad makes data entry quick and easy Includes: - Four USB Ports-two External & two Internal - Ethernet - RS-232 Technical specifications 1-4 independently programmable channels Measuring Accuracy: 0.25% of span typical Selectable °C or °F temperature scale 12.1” (30 cm) color flat panel touch screen display Resolution: 0.1°C, 0.1%RH, 0.01 for other linear applications Real time clock included Sample Rate: Process variable sampled every 0.1 seconds Proportional Band: Programmable 1.0° to 300° Control Method:  Digital Intervals: Unlimited Interval Resolution: 1 sec to 99 hrs,59 min with 1 second resolution - RS-232 - 10+ Years Data Storage - Product Temperature Control - Event Relay Board Operating Modes: Automatic or Manual Program Storage:  Unlimited Program Loops: - Up to 64 loops per program Loops can be repeated up to 9,999 times program - Up to 64 nested loops are allowed per
    Read More
  • Drug Stability Test Drug Stability Test
    Oct 31, 2024
    Drug Stability Test The effectiveness and safety of drugs have attracted much attention, and it is also a livelihood issue that the country and the government attach great importance to. The stability of drugs will affect the efficacy and safety. In order to ensure the quality of drugs and storage containers, stability tests should be performed to determine their effective time and storage state. Stability test mainly studies whether the quality of drugs is affected by environmental factors such as temperature, humidity and light, and whether it changes with time and the correlation between them, and studies the degradation curve of drugs, according to which the effective period is presumed to ensure the effectiveness and safety of drugs when used. This article collects the standard information and test methods required for various stability tests for customers' reference. First, drug stability test criteria Storage conditions of drugs:   Storage conditions (Note 2) Long-term experiment 25℃±2℃ / 60%±5%RH or 30℃±2℃ /65%±5% RH Accelerated test 40℃±2℃ / 75%±5%RH Middle test (Note 1) 30℃±2℃ / 65%±5%RH Note 1: If the long-term test condition has been set at 30℃±2℃/65% ±5%RH, there is no middle test; if the long-term storage condition is 25℃±2℃/ 60% ±5%RH, and there is a significant change in the accelerated test, then middle test should be added. And should be assessed against the criteria of "significant change". Note 2: Sealed impervious containers such as glass ampoules can be exempted from humidity conditions. Unless otherwise determined, all tests shall be carried out in accordance with the stability test plan in the interim test. The accelerated test data should be available for six months. The minimum duration of the stability test is 12 months for the middle test and the long-term test.   Store in refrigerator:   Storage conditions Long-term experiment 5℃±3℃ Accelerated test 25℃±2℃ / 60%±5%RH   Stored in freezer:   Storage conditions Long-term experiment -20℃±5℃ Accelerated test 5℃±3℃ If the product containing water or solvents that may be subject to solvent loss is packaged in a semi-permeable container, the stability assessment should be conducted under low relative humidity for a long period of time, or an middle test of 12 months, and an accelerated test of 6 months, in order to prove that the drug placed in the semi-permeable container can withstand the low relative humidity environment.   Containing water or solvents   Storage conditions Long-term experiment 25℃±2℃ / 40%±5%RH or 30℃±2℃ /35%±5% RH Accelerated test 40℃±2℃;≤25%RH Middle test (Note 1) 30℃±2℃ / 35%RH±5%RH Note 1: If the long-term test condition is 30℃±2℃ / 35%±5%RH, there is no middle test.   The calculation of the relative water loss rate at a constant temperature of 40℃ is as follows: Substituted relative humidity (A) Control relative humidity (R) Water loss rate ratio ([1-R]/[1-A]) 60%RH 25%RH 1.9 60%RH 40%RH 1.5 65%RH 35%RH 1.9 75%RH 25%RH 3.0 Illustration: For aqueous drugs placed in semi-permeable containers, the water loss rate at 25%RH is three times that of 75%RH.   Second, Drug stability solutions Common drug stability test criteria (Source: Food and Drug Administration, Ministry of Health and Welfare) Item Storage conditions Long-term experiment 25°C /60% RH Accelerated test 40°C /75%RH Middle test 30°C/65%RH   (1) Wide temperature range test Item Storage conditions Long-term experiment Low or sub-zero temperature conditions Accelerated test Room temperature and humidity or low temperature conditions   (2) Test equipment 1. Constant temperature and humidity test chamber 2. Drug stability test chamber
    Read More
  • Inverter- Reliability Test Inverter- Reliability Test
    Oct 11, 2024
    Inverter- Reliability Test Inverter- reliability test also known as voltage converter, its function is to convert DC low voltage into AC high voltage, some electronic equipment must be driven by AC power, but we provide is DC power, at this time you must use the Inverter, direct current into alternating current to drive the electronic parts. Inverter- reliability test also known as voltage converter, its function is to convert DC low voltage into AC high voltage, some electronic equipment must be driven by AC power, but we provide is DC power, at this time you must use the Inverter, direct current into alternating current to drive the electronic parts. Relevant test conditions: Item temperature time other Initial test at normal temperature 25 ℃ TIME≥2 hours - Low temperature initial test 0 ℃ or -5 °C TIME≥2 hours - High temperature initial test 60℃ TIME≥2 hours - High temperature and high humidity test 40℃/95%RH 240 hours - High temperature storage test 70℃ TIME≥96 hours or 240 hours - Low temperature storage test -1 -20°C TIME≥96 hours - Low temperature storage test -2 -40℃ 240 hours - High temperature and high humidity storage test 40℃/90%RH TIME≥96 hours - Temperature cycle test -20℃~ 70℃ 5 cycle Room temperature ↓-20 ℃(4 hours)↓ Room temperature (90%RH.4 hours)↓70°C(4 hours)↓ Room temperature (4 hours) High temperature load test 55 ℃ equivalent load, 1,000 hours - Life test 40°C MTBF≥40000 hours - on/off test (power cycle) - - 1min:on, 1min:off, 5,000 cycles using equivalent load Vibration test - - Acceleration 3q, frequency 10~55HZ, X, Y, Z three directions 10 minutes each, a total of 30 minutes Impact test - - Acceleration of 80g, 10 ms each time, Three times in X, Y, Z directions Note 1: The tested module should be placed at normal (15~35° C,45~65%RH) for one hour before testing Applicable equipment: 1. High and low temperature test chamber 2. High temperature and high humidity test chamber 3. Rapid temperature cycle test chamber                
    Read More

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
submit

home

products

WhatsApp

contact us