Information Communication Environment Test Solution
The statistical analysis shows that the failure of electronic components accounts for 50% of the failure of electronic complete machine, and the reliability detection technology still faces many challenges.
Industry
Test object
Use
Technology
Solution
IT Communication
Transmission switching equipment
Inspect
High temperature placement test
High and low temperature (&humidity) test chamber
Aging test
High and low temperature (&humidity) test chamber
Evaluate
Thermal cycling test
High and low temperature (&humidity) test chamber
Tellcordia test
High and low temperature (&humidity) test chamber
Thermal cycling test
Rapid temperature (&humidity)change test chamber
Mobile communication terminal
Inspect
Finished operation test
High and low temperature (&humidity) test chamber
Finished operation test
Rapid temperature (&humidity)change test chamber
Evaluate
Temperature and humidity test
High and low temperature (&humidity) test chamber
Computer
Inspect
Finished product screening
Rapid temperature (&humidity)change test chamber
High temperature placement test
High and low temperature (&humidity) test chamber
Aging test
High and low temperature (&humidity) test chamber
External computer storage device
Inspect
Component screening
High and low temperature (&humidity) test chamber
Component screening
Rapid temperature (&humidity)change test chamber
Evaluate
Ensure operation test within temperature and humidity range
High and low temperature (&humidity) test chamber
Ensure operation test within temperature and humidity range
Rapid temperature (&humidity)change test chamber
Lab Companion-Rapid Temperature Cycling Test Chamber
Introduction of Lab Companion
With over 20 years of experience, Lab Companion is a world class manufacturer of environmental chambers and an accomplished supplier of turn-key test systems and equipment. All our chambers build on Lab Companion’s reputation for long life and exceptional reliability.
With a scope of design, manufacture and service, Lab Companion has established a quality management system that complies with the International Quality System Standard ISO 9001:2008. Lab Companion’s equipment calibration program is accredited to the International Standard ISO 17025 and the American National Standard ANSI/NCSL-Z-540-1 by A2LA. A2LA is a full member and signatory of the International Laboratory Accreditation Cooperation (ILAC), the Asia Pacific Laboratory Accreditation (APLAC) and the European Cooperation for Accreditation (EA).
Lab Companion’s SE-Series Environmental Test Chambers offer a significantly enhanced airflow system, which provides better gradients and improved product temperature change rates. These chambers utilize Thermotron’s flagship 8800 Programmer/Controller featuring a high resolution 12.1” flat panel display with touch screen user interface, expanded capabilities to graph, data log, edit, access on-screen help, and long term hard drive data storage.
Not only do we offer the highest quality products, we also provide ongoing support designed to keep you up and running long after the initial sale. We provide factory direct local service with an extensive inventory of the parts you might need.
Performance
Temperature range: -70°C to +180°C
Performance: With 23 Kg aluminum load (IEC60068-3-5), the rising rate from +85°C to -40°C is 15℃/min; the cooling rate from -40°C to +85°C is15℃/min too.
Temperature control:± 1°C Dry bulb temperatures from control point after stabilization at the control sensor
Performance is based on an ambient condition of 75°F (23.9°C) and 50% RH
Cooling/Heating Performance based on measurement at the control sensor in the supply air stream
Constructure
Interior
Nonmagnetic Series 300 stainless steel with a high nickel content
Internal seams heliarc welded for hermetic sealing of the liner
Corners and seams designed to allow for expansion and contraction under the temperature extremes encountered
Condensate drain located in the liner floor and under the conditioning plenum
Chamber base is fully welded
“Ultra-Lite” non-settling fiberglass insulation
One adjustable interior stainless steel shelf is standard
Exterior
Die-formed treated sheet steel
Metal access covers provided for easy opening doors to electrical components
Finish water-based, air dry lacquer, sprayed over a cleaned and primed surface
Easy lift-off hinged access doors for servicing the refrigeration system
One 12.5 cm diameter access port with interior weld and removable insulating plug mounted in right hand side wall accessories on hinged door for easy access
Features
Chamber Operation clearly displays helpful run-time information
Graphing Screen offers expanded capabilities, enhanced programming and reporting
System Status displays crucial refrigeration system parameters
Program Entry makes it easy to load, view and edit profiles
Set Up quick-step wizards make profile entry easy
Pop-up Refrigeration Charts for handy reference
Therm-Alarm® provides over & under temperature alarm protection
Activity Log Screen provides comprehensive equipment history
Web Server allows internet access to equipment via Ethernet
User-Friendly Pop-up Key Pad makes data entry quick and easy
Includes:
- Four USB Ports-two External & two Internal
- Ethernet
- RS-232
Technical specifications
1-4 independently programmable channels
Measuring Accuracy: 0.25% of span typical
Selectable °C or °F temperature scale
12.1” (30 cm) color flat panel touch screen display
Resolution: 0.1°C, 0.1%RH, 0.01 for other linear applications
Real time clock included
Sample Rate: Process variable sampled every 0.1 seconds
Proportional Band: Programmable 1.0° to 300°
Control Method: Digital
Intervals: Unlimited
Interval Resolution: 1 sec to 99 hrs,59 min with 1 second resolution
- RS-232
- 10+ Years Data Storage
- Product Temperature Control
- Event Relay Board
Operating Modes: Automatic or Manual
Program Storage: Unlimited
Program Loops:
- Up to 64 loops per program
Loops can be repeated up to 9,999 times program
- Up to 64 nested loops are allowed per
Drug Stability Test
The effectiveness and safety of drugs have attracted much attention, and it is also a livelihood issue that the country and the government attach great importance to. The stability of drugs will affect the efficacy and safety. In order to ensure the quality of drugs and storage containers, stability tests should be performed to determine their effective time and storage state. Stability test mainly studies whether the quality of drugs is affected by environmental factors such as temperature, humidity and light, and whether it changes with time and the correlation between them, and studies the degradation curve of drugs, according to which the effective period is presumed to ensure the effectiveness and safety of drugs when used. This article collects the standard information and test methods required for various stability tests for customers' reference.
First, drug stability test criteria
Storage conditions of drugs:
Storage conditions (Note 2)
Long-term experiment
25℃±2℃ / 60%±5%RH or
30℃±2℃ /65%±5% RH
Accelerated test
40℃±2℃ / 75%±5%RH
Middle test (Note 1)
30℃±2℃ / 65%±5%RH
Note 1: If the long-term test condition has been set at 30℃±2℃/65% ±5%RH, there is no middle test; if the long-term storage condition is 25℃±2℃/ 60% ±5%RH, and there is a significant change in the accelerated test, then middle test should be added. And should be assessed against the criteria of "significant change".
Note 2: Sealed impervious containers such as glass ampoules can be exempted from humidity conditions. Unless otherwise determined, all tests shall be carried out in accordance with the stability test plan in the interim test.
The accelerated test data should be available for six months. The minimum duration of the stability test is 12 months for the middle test and the long-term test.
Store in refrigerator:
Storage conditions
Long-term experiment
5℃±3℃
Accelerated test
25℃±2℃ / 60%±5%RH
Stored in freezer:
Storage conditions
Long-term experiment
-20℃±5℃
Accelerated test
5℃±3℃
If the product containing water or solvents that may be subject to solvent loss is packaged in a semi-permeable container, the stability assessment should be conducted under low relative humidity for a long period of time, or an middle test of 12 months, and an accelerated test of 6 months, in order to prove that the drug placed in the semi-permeable container can withstand the low relative humidity environment.
Containing water or solvents
Storage conditions
Long-term experiment
25℃±2℃ / 40%±5%RH or 30℃±2℃ /35%±5% RH
Accelerated test
40℃±2℃;≤25%RH
Middle test (Note 1)
30℃±2℃ / 35%RH±5%RH
Note 1: If the long-term test condition is 30℃±2℃ / 35%±5%RH, there is no middle test.
The calculation of the relative water loss rate at a constant temperature of 40℃ is as follows:
Substituted relative humidity (A)
Control relative humidity (R)
Water loss rate ratio ([1-R]/[1-A])
60%RH
25%RH
1.9
60%RH
40%RH
1.5
65%RH
35%RH
1.9
75%RH
25%RH
3.0
Illustration: For aqueous drugs placed in semi-permeable containers, the water loss rate at 25%RH is three times that of 75%RH.
Second, Drug stability solutions
Common drug stability test criteria
(Source: Food and Drug Administration, Ministry of Health and Welfare)
Item
Storage conditions
Long-term experiment
25°C /60% RH
Accelerated test
40°C /75%RH
Middle test
30°C/65%RH
(1) Wide temperature range test
Item
Storage conditions
Long-term experiment
Low or sub-zero temperature conditions
Accelerated test
Room temperature and humidity or low temperature conditions
(2) Test equipment
1. Constant temperature and humidity test chamber
2. Drug stability test chamber
Inverter- Reliability Test
Inverter- reliability test also known as voltage converter, its function is to convert DC low voltage into AC high voltage, some electronic equipment must be driven by AC power, but we provide is DC power, at this time you must use the Inverter, direct current into alternating current to drive the electronic parts. Inverter- reliability test also known as voltage converter, its function is to convert DC low voltage into AC high voltage, some electronic equipment must be driven by AC power, but we provide is DC power, at this time you must use the Inverter, direct current into alternating current to drive the electronic parts.
Relevant test conditions:
Item
temperature
time
other
Initial test at normal temperature
25 ℃
TIME≥2 hours
-
Low temperature initial test
0 ℃ or -5 °C
TIME≥2 hours
-
High temperature initial test
60℃
TIME≥2 hours
-
High temperature and high humidity test
40℃/95%RH
240 hours
-
High temperature storage test
70℃
TIME≥96 hours or 240 hours
-
Low temperature storage test -1
-20°C
TIME≥96 hours
-
Low temperature storage test -2
-40℃
240 hours
-
High temperature and high humidity storage test
40℃/90%RH
TIME≥96 hours
-
Temperature cycle test
-20℃~ 70℃
5 cycle
Room temperature ↓-20 ℃(4 hours)↓ Room temperature (90%RH.4 hours)↓70°C(4 hours)↓ Room temperature (4 hours)
High temperature load test
55 ℃
equivalent load, 1,000 hours
-
Life test
40°C
MTBF≥40000 hours
-
on/off test (power cycle)
-
-
1min:on, 1min:off, 5,000 cycles using equivalent load
Vibration test
-
-
Acceleration 3q, frequency 10~55HZ, X, Y, Z three directions 10 minutes each, a total of 30 minutes
Impact test
-
-
Acceleration of 80g, 10 ms each time, Three times in X, Y, Z directions
Note 1: The tested module should be placed at normal (15~35° C,45~65%RH) for one hour before testing
Applicable equipment:
1. High and low temperature test chamber
2. High temperature and high humidity test chamber
3. Rapid temperature cycle test chamber