Xenon lamp weathering test chamber  is an important means of scientific research and production process to screen the formula to optimize the composition of the product, but also an important element of product quality inspection, the application of materials such as coatings, plastics, aluminum-plastic panels, as well as automotive safety glass and other product standards are required to do the weathering test. The main factors causing material aging is sunlight and moisture, weathering test chamber can simulate the hazards caused by sunlight, rain and dew, the use of xenon lamps to simulate the effect of sunlight, the use of condensing humidity to simulate rain and dew, the material under test is placed in a certain temperature of light and moisture alternating cyclic program for testing, with a few days or weeks can reproduce the hazards of the outdoor months and even years to appear, the manual Accelerated weathering test data can help in the selection of new materials, the modification of existing materials, and the evaluation of how changes in formulation affect the durability of products.

  • Item No :

    Q8-SUN-(volume)
  • Order(MOQ) :

    1
  • Product Origin :

    China
  • Lead Time :

    30 working days

 

1.Standard

GB/T1865-97

GB/T9344-88

GB/T16422.2

GB/T2423.24-1995

ASTMG155

ISO10SB02/B04

SAEJ2527

SAEJ2412

 

2.Condition

2.1 RT:-15℃~+50℃

2.2 Room relative humidity: 10~80%(20℃)

 

3.Main function

Xenon lamp weatherproof test chamber is mainly used to test the outdoor products of sunlight radiation protection test, to ensure that the products under test can withstand the harsh outdoor environment aging test, so that the products can be safe and reliable normal operation.

 

4.Technical parameter

4.1 temperature range:RT+10℃~70℃

4.2 humidity range:50~90% R•H

4.3 blackboard temperature:63~100℃   ±3℃     

4.4 temperature fluctuation/deviation:≤±0.5℃

4.5  temperature uniformity:≤ ±2.0℃

4.6 inside/internal dimensions:W:  800mm  × H:  950mm  × D: 800mm

4.7 outside/external dimensions:W:  1100mm  × H: 2000mm × D: 1630mm

4.8 Types of light source: imported air-cooled xenon lamp (the USA Q-Panel)

4.9 Xenon lamp quantity:three lamps(three standby lamps)

4.10 rainfall time:0~9999min, adjustable

4.11 Rainfall period:0~240min,  adjustable interval

4.12 Spray time(Water spray time/no water spray time):18min/102min

4.13 Rain water pressure:0.12~0.15Mpa

4.14 aperture of the nozzle:Ф0.8mm

4.15  Xenon Lamp Power:1.8KW*3支branches=5.4 KW

4.16 heating power:2KW

4.17 humidification power:0.75KW

4.18 size of the sample rack tray:800*800mm

4.19 distance between sample holder and lamp:230~800mm

4.20 wave length:290~800nm  ;Xenon lamp radiation intensity:500~1200W/m2

4.21 irradiance(optional for Radiometer), lighting time:1~999h、m、s  ;radiation intensity:60W / m2,

The maximum is not more than 130W/ m2(the average ultraviolet irradiance of the spectral wavelength of 290nm ~ 400nm)

The maximum irradiance of the ultraviolet spectral wavelength is not more than 2W/ m2 when the spectral wavelength is less than 300nm

 

 

Xenon lamp climate test chamber configuration requirements are as follows:

 

1.1 Main body

1.1 The exterior chamber is processed by high-quality (t=1mm) A3 steel plate CNC machine tool, and the surface is sprayed with plastic coating.

1.1.2 The inner chamber is imported (t=1mm) high-quality 304 stainless steel plate.

1.1.3 Insulation material: high density glass fiber cotton. The thickness is 80mm

1.1.4 Mixing system: Fan motor with long axis, stainless steel multi-wing impeller resistant to high and low temperature, aim to the strength of the convection vertical diffusion cycle.

1.1.5 A double-layer high tensile sealing strip with high temperature resistance is used between the door and the box to ensure the air tightness of the test area

1.1.6 Non-reactive door handles is set up for easy operation

1.1.7 The bottom of the machine adopts high quality fixable PU movable wheel.

1.1.8 The observation window adopts multi-layer hollow tempered glass (It is  clear to observe the test process)

1.2 Heating, humidifying, cooling and dehumidifying

Heating:

1.2.1 Far infrared high speed heating (2KW×1) electric heater made of nickel alloy is adopted

1.2.2 High temperature system, humidity system and light system are completely independent ( Each other without interference)

1.2.3 The output power of controlling temperature and humidity are calculated by microcomputer to improve power efficiency

Humidifying:

1.2.4 external steam boiler humidifier

1.2.5 With automatic water level compensation, water shortage alarm system

1.2.6 Far infrared stainless steel high-speed heating (0.75KW×1) electric heat pipe

1.2.7 The humidity control is coordinated by P.I. D + S.S.R system with the same channel

Cooling and dehumidifying:

1.2.8 Compressor: fully enclosed French Tecumseh

1.2.9 Cooling Mode: mechanical single-machine cooling

1.2.10 Condensing Mode: Air cooling

1.2.11 Refrigerant: R404A (Environment-friendly)

1.2.12 All system pipes should be ventilated and pressurized for 48 hours of leakage detection test.

1.2.13 The heating and cooling systems are independent

1.2.14 Inner spiral refrigerant copper pipe.

1.2.15 Finned Slope Evaporator with automatic defrosting system

1.2.16 Filter dryer, refrigerant flow window, repair valve, oil separator, solenoid valve, liquid storage cylinder are all imported originally

1.2.17 Dehumidification system: Adapt the evaporator coil contacting with temperature layer dehumidification method

1.3 Circuit control system

1.3.1 Temperature and humidity control instrument adopts Q8 touch screen xenon lamp programmable controller.

1.3.2 Accuracy: 0.1℃(display range)

1.3.3 Resolution: ±0.1℃;

1.3.4 Temperature sensor: PT100 platinum resistance thermoscope;

1.3.5 Control mode: heat balance mode controls temperature and humidity; All electrical appliances are made of (Schneider) series products

1.3.6 Temperature and humidity control is coordinated by the P.I. D+S.S.R system with the same channel

1.3.7 With the function of automatic calculation, the temperature and humidity change conditions can be corrected immediately to ensure more accurate and stable control

1.4 Protection device

1.4.1 Fan Overheat protection

1.4.2 Deficient or reverse Phase of overall device protection

1.4.3 Overload cooling systems protection

1.4.4 Overpressure cooling systems protection

1.4.5 Overtemperature Protection

1.4.6 Overheat and overcurrent pump protection

1.4.7 Other leakage

1.4.8 Water shortage indicator

1.4.9 Automatic shutdown after fault alarm

1.5 Lighting System

1.5.1 Blackboard Thermometer: mental blackboard thermometer;

1.5.2 Xenon lamp tube: Adapt qualified American imported lamp tube, life of 1600-2000 hours.

1.5.3 Control of irradiance: Both automatic control of the radiometer and manual adjustment of power are available.

1.6 Water spraying circulation system

1.6.1 Water quality: Deionized water (solid less than 20ppm)

1.6.2 With water level display of water storage tank

1.6.3 The ejected water is recyclable

1.6.4 The water spray pressure is adjustable between 0.12 and 0.15Mpa

1.6.5 Two sprinkler heads are installed at the top of the studio

 

Weather Resistance Test Chamber

 

NUMBER

Indication Content

Content Description

Graph View

Move to the program curve view, history curve and setting screen.

Main View

Move to the fixed value/program control screen.

Function & Fix

Move to the additional function and operation mode setting screen.

Log View

Move to the operation record view screen.

Prog Setting

Move to the group setting menu screen.

Reserve Set

Move to the current time and scheduled running time setting screen.

Advanced Setting

Move to the menu screen of file backup, communication setting, manual debugging, fault recording and screen capture browsing.

About...

Move to the screen for viewing user information and current touch screen system status.

 

 

 

 

 

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products

Xenon lamp climate test chamber
Xenon lamp weathering test chamber

  Xenon lamp weathering test chamber  is an important means of scientific research and production process to screen the formula to optimize the composition of the product, but also an important element of product quality inspection, the application of materials such as coatings, plastics, aluminum-plastic panels, as well as automotive safety glass and other product standards are required to do the weathering test. The main factors causing material aging is sunlight and moisture, weathering test chamber can simulate the hazards caused by sunlight, rain and dew, the use of xenon lamps to simulate the effect of sunlight, the use of condensing humidity to simulate rain and dew, the material under test is placed in a certain temperature of light and moisture alternating cyclic program for testing, with a few days or weeks can reproduce the hazards of the outdoor months and even years to appear, the manual Accelerated weathering test data can help in the selection of new materials, the modification of existing materials, and the evaluation of how changes in formulation affect the durability of products.

read More

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
submit

home

products

WhatsApp

contact us