banner
Home

Temperature and Humidity Cycling Test Chamber

Temperature and Humidity Cycling Test Chamber

  • Reliability - Environment Reliability - Environment
    Sep 28, 2024
    Reliability - Environment Reliability analysis is based on quantitative data as the basis of product quality, through the experimental simulation, the product in a given time, specific use of environmental conditions, the implementation of specific specifications, the probability of successful completion of work objectives, to quantitative data as the basis for product quality assurance. Among them, environmental testing is a common analysis item in reliability analysis. Environmental reliability testing is a test performed to ensure that the functional reliability of a product is maintained during the specified life period, under all circumstances in which it is intended to be used, transported or stored. The specific test method is to expose the product to natural or artificial environmental conditions, to evaluate the performance of the product under the environmental conditions of actual use, transportation and storage, and to analyze the impact of environmental factors and their mechanism of action. Sembcorp's Nanoreliability Analysis laboratory mainly evaluates IC reliability by increasing temperature, humidity, bias, analog IO and other conditions, and selecting conditions to accelerate aging according to IC design requirements. The main test methods are as follows: TC temperature cycle test Experimental standard: JESD22-A104 Objective: To accelerate the effect of temperature change on the sample Test procedure: The sample is placed in a test chamber, which cycles between specified temperatures and is held at each temperature for at least ten minutes. The temperature extremes depend on the conditions selected in the test method. The total stress corresponds to the number of cycles completed at the specified temperature. capacity of equipment Temperature Range  -70℃—+180℃ Temperature Change Rate 15℃/min linear Internal Volume   160L Internal Dimension  W800*H500 * D400mm External Dimension W1000 * H1808 * D1915mm Quantity of sample  25 / 3lot Time/pass   700 cycles / 0 Fail2300 cycles / 0 Fail BLT high temperature bias test Experimental standard: JESD22-A108 Objective: The influence of high temperature bias on samples Test process: Put the sample into the experimental chamber, set the specified voltage and current limit value in power supply, try run at room temperature, observe whether the limited current occurs in power supply, measure whether the input chip terminal voltage meets the expectation, record the current value at room temperature, and set the specified temperature in chamber. When the temperature is stable at the set value, power on at high temperature and record the high temperature current value Equipment capacity: Temperature Range  +20℃—+300℃ Internal Volume   448L Internal Dimension  W800*H800 * D700mm External Dimension W1450 * H1215 * D980mm Quantity of sample  25 / 3lot Time/pass   Case Temperature 125℃ ,1000hrs/ 0 Fail HAST highly accelerated stress test Experimental standard: JESD22-A110/A118 (EHS-431ML, EHS-222MD) Objective: HAST provides constant multiple stress conditions, including temperature, humidity, pressure, and bias. Carried out to assess the reliability of non-enclosed packaged equipment operating in humid environments. Multiple stress conditions can accelerate the infiltration of moisture through the encapsulation mold compound or along the interface between the external protective material and the metal conductor passing through the encapsulation. When water reaches the surface of the bare piece, the applied potential sets up an electrolytic condition that corrodes the aluminum conductor and affects the DC parameters of the device. Contaminants present on the chip surface, such as chlorine, can greatly accelerate the corrosion process. In addition, too much phosphorus in the passivation layer can also react under these conditions. Device 1 and device 2 Equipment capacity: Quantity of sample  25 / 3lot Time/pass   130℃,85%RH ,96hrs/ 0 Fail 110℃,85%RH ,264hrs/ 0 Fail Device 1 Temperature Range -105℃—+142.9℃ Humidity Range  75%RH—100%RH Pressure Range  0.02—0.196MPa Internal Volume   51L Internal Dimension  W355*H355 * D426mm External Dimension W860 * H1796 * D1000mm Device 2 Temperature Range -105℃—+142.9℃ Humidity Range  75%RH—100%RH Pressure Range  0.02—0.392MPa Internal Volume   180L Internal Dimension  W569*H560 * D760mm External Dimension W800 * H1575 * D1460mm THB temperature and humidity cycle test Experimental standard: JESD22-A101 Objective: The influence of temperature and humidity change on the sample Experimental process: Put the sample into the experimental chamber, set the specified voltage and current limit value in power supply, try run at room temperature, observe whether the limited current occurs in power supply, measure whether the input chip terminal voltage meets the expectation, record the current value at room temperature, and set the specified temperature in chamber. When the temperature is stable at the set value, power on at high temperature and record the high temperature current value Equipment capacity: Temperature Range -40℃—+180℃ Humidity Range  10%RH—98%RH Temperature Conversion Rate 3℃/min Internal Volume   784L Internal Dimension  W1000*H980 * D800mm External Dimension W1200 * H1840 * D1625mm Quantity of sample  25 / 3lot Time/pass   85℃,85%RH ,1000hrs/ 0 Fail Procedure temperature and humidity cycle, there has no humidity when temperature over 100℃  TSA&TSB temperature shock test Experimental standard: JESD22-A106 Objective: To accelerate the effect of temperature change on the sample Test process: The sample is put into the test chamber, and the specified temperature is set inside the chamber. Before heating up, it is confirmed that the sample has been fixed on the mold, which has prevented damage due to the sample falling into the chamber during the experiment. Equipment capacity:   TSA  TSB Temperature Range -70℃—+200℃  -65℃—+200℃ Temperature Change Rate ≤5min   <20S Internal Volume 70L  4.5L    Internal Dimension   W410*H460 * D3700mm   W150*H150 * D200mm External Dimension W1310 * H1900 * D1770mm  W1200 * H1785 * D1320mm  
    Read More

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
submit

home

products

WhatsApp

contact us