banner
Home

temperature and humidity controlled chamber

temperature and humidity controlled chamber

  • EC-105HTP,MTP,MTHP, High and low temperature constant temperature bath (1000L) EC-105HTP,MTP,MTHP, High and low temperature constant temperature bath (1000L)
    Nov 14, 2014
    EC-105HTP,MTP,MTHP, High and low temperature constant temperature bath (1000L) Project Type Series HT MT MTH function Temperature occurs in a way Dry wet bulb method Temperature range -20 ~ + 100 ℃ -40 ~ + 100 ℃ -40 ~ + 150 ℃ Range of temperature  Below the + 100℃ ± 0.3 ℃ +Above the 101℃ ― ± 0.5 ℃ Temperature distribution Below the + 100℃ ± 1.0 ℃ Above the + 101℃ ― ± 2.0 ℃ The temperature drops the time +20 ~ -20 ℃ Within 60 minutes +20 ~ -40 ℃ Within 9 0 minutes +20 ~ -40 ℃ Within 9 0 minutes Temperature rise time -20 ~ + 100 ℃ Within 45 minutes -40 ~ + 100 ℃ Within 50 minutes -40 ~ + 150 ℃ Within 75 minutes The internal volume of the uterus was tested 1000L Test room inch method (width, depth and height) 1000mm × 1000mm × 1000mm Product inch method (width, depth and height) 1400mm × 1370mm × 1795mm Make the material External outfit Test room control panel machine room Cold steel plate, cold steel plate beige (Color table 2.5Y8 / 2) Inside Stainless steel plate (SUS304,2B polished) Broken heat material Test room Hard synthetic resin ― glass wool door Hard synthetic resin foam cotton, glass cotton Project Type Series HT MT MTH Cooling dehumidifying device  Cooling-down method Mechanical section shrinkage mode  Cooling medium R404A compressor Output (number of units) 0.75kW (1) 1.5kW (1) Cooling and dehumidifier Multi-channel mixed heat sink type The condenser Multi-channel mixed radiator plate type (air cooling type) Calorifier Form Nickel-chromium heat-resistant alloy heater Volume 3.5kW Blower Form Multi-channel mixed radiator plate type (air cooling type) Motor capacity 40W  Controller The temperature is set -22.0 ~ + 102.0 ℃ -42.0 ~ + 102.0 ℃ -42.0 ~ + 152.0 ℃ Humidity is set 0 ~ 98%RH (But the temperature of the wet and dry bulb is 10-85 ℃ ) Time setting Fanny 0 ~ 999 Time 59 minutes (formula) 0 ~ 20000 Time 59 minutes (formula formula) Set decomposition energy Temperature 0.1℃, humidity 1% RH for 1 min Indicate accuracy Temperature ± 0.8℃ (tp.), humidity ± 1% RH (tp.), time ± 100 PPM Vacation type Value or program Stage number 20-stage / 1 program The number of procedures The maximum number of incoming force (RAM) programs is 32 programs The maximum number of internal ROM programs is 13 programs Round-trip number  98 times maximum or unlimited Number of round-trip repeats Maximum 3 times Displace the end Pt 100Ω(at 0 ℃), gradeB(JIS C 1604-1997) Control action When splitting the PID action Endovirus function Early delivery function, standby function, setting value maintenance function, power outage protection function, Power action selection function, maintenance function, transportation round-trip function, Time delivery function, time signal output function, overrising and overcooling prevention function, Abnormal representation function, external alarm output function, setting paradigm representation function, Transport type selection function, the calculation time represents the function, the slot lamp lamp function Project Type Series HT MT MTH Control panel Equipment machine LCD operating panel (type contact panel), Represents lamp (power, transport, abnormal), test power supply terminal, external alarm terminal, Time signal output terminal, power cord connector  Protective device Refrigerating cycle Overload protection device, high blocking device Calorifier Temperature over-rise protection device, temperature fuse Blower Overload protection device Control panel Leakage breaker for power supply, fuse (for heater, humidifier), Fuse (for operating loop), temperature rise protection device (for testing), Temperature rise overcooling prevention device (test material, in microcomputer) Offproducts (sets) House receiving (4), house board (2), operation instructions (1) Equipment products Adventitia hard borosilicate glass  270mm× 190mm 2   Cable hole 内径  50mm 1   The trough inside the lamp AC100V 15W White hot ball 2   Wheel   4   Horizontal adjustment   4   Electrovirus characteristics  Source *  AC  three-phase 380V  50Hz Maximum load current 13A 15A Capacity of the leakage breaker for the power supply 25 A Sensory current 30mA Power distribution thickness 8mm2 14mm2 Rubber insulation hose Coarseness of grounding wire 3.5mm2 5.5mm2  Tubing drain-pipe * PT1/2 Product weight 470kg 540kg
    Read More
  • EC-35EXT, Superior constant temperature bath (306L) EC-35EXT, Superior constant temperature bath (306L)
    Nov 14, 2014
    EC-35EXT, Superior constant temperature bath (306L) Project Type Series EXT Function Temperature occurs in a way Dry wet bulb method Temperature range -70 ~ +150 ℃ Range of temperature Below the + 100℃ ±0.3 ℃ Above the + 101℃ ±0.5 ℃ Temperature distribution Below the + 100℃ ±0. 7 ℃ Above the + 101℃ ±1.0 ℃ The temperature drops the time +125 ~-55 ℃ Within 18 points (10℃ / point average temperature change) Temperature rise time -55 ~+125 ℃ Within 18 minutes (10℃ / minute) The internal volume of the uterus was tested 306L Test room inch method (width, depth and height) 630mm × 540mm × 900mm Product inch method (width, depth and height) 1100mm × 1960mm × 1900mm Make the material External outfit Test room control panel machine room Cold interductile steel plate is dark gray Inside Stainless steel plate (SUS304,2B polished) Broken heat material Test room Hard synthetic resin door Hard synthetic resin foam cotton, glass cotton Project Type Series EXT Cooling dehumidifying device Cooling-down method Mechanical section shrinkage and freezing mode and binary freezing mode Cooling medium;coolant Single segment side R 404A Binary high temperature / low temperature side R 404A / R23 Cooling and dehumidifier Multi-channel mixed heat sink type The condenser (water-cooled) Calorifier Form Nickel-chromium heat-resistant alloy heater Blower Form Stir fan Controller The temperature is set -72.0 ~ + 152.0 ℃ Time setting Fanny 0 ~ 999 Time 59 minutes (formula) 0 ~ 20000 Time 59 minutes (formula formula) Set decomposition energy Temperature was 0.1℃ for 1 min Indicate accuracy Temperature ± 0.8℃ (typ.), time ± 100 PPM Vacation type Value or program Stage number 20-stage / 1 program The number of procedures The maximum number of incoming force (RAM) programs is 32 programs The maximum number of internal ROM programs is 13 programs式 Round-trip number Max. 98, or unlimited Number of round-trip repeats Maximum 3 times Displace the end Pt 100Ω ( at 0 ℃ ),grade ( JIS C 1604-1997 ) Control action When splitting the PID action Endovirus function Early delivery function, standby function, setting value maintenance function, power outage protection function, Power action selection function, maintenance function, transportation round-trip function, Time delivery function, time signal output function, overrising and overcooling prevention function, Abnormal representation function, external alarm output function, setting paradigm representation function, Transport type selection function, the calculation time represents the function, the slot lamp lamp function Project Type Series EXH Control panel Equipment machine LCD operating panel (type contact panel), Represents lamp (power, transport, abnormal), test power supply terminal, external alarm terminal, Time signal output terminal, power cord connector  Protective device Refrigerating cycle Overload protection device, high blocking device Calorifier Temperature over-rise protection device, temperature fuse Blower Overload protection device Control panel Leakage breaker for power supply, fuse (heater,), Fuse (for operating loop), temperature rise protection device (for testing), Temperature rise overcooling prevention device (test material, in microcomputer) Pay belongs to the product Test material shed shed by * 8 Stainless steel Shshed (2), shed (4) Fuse Operating loop Protection Fuses (2) Operating specification ( 1 )  Else Bolus (Cable hole: 1) Equipment products Adventitia Heat-resistant glass: 270mm: 190mm 1   Cable hole Inner diameter of 50mm 1   The trough inside the lamp AC100V 15W White hot ball 1   Wheel   6   Horizontal adjustment   6   Electrovirus characteristics Power supply is * 5.1  AC Three-phase  380V  50Hz Maximum load current 60A Capacity of the leakage breaker for the power supply 80A Sensory current  30mA Power distribution thickness 60mm2 Rubber insulation hose Coarseness of grounding wire 14mm2 Cooling water at * 5.3 Water yield 5000 L /h (When the cooling water inlet temperature is 32℃) water pressure 0.1 ~ 0.5MPa Side pipe diameter of the device PT1 1/4  Tubing Drain-pipe  * 5.4 PT1/2 Product weight 700kg
    Read More

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
submit

home

products

WhatsApp

contact us