banner
Home

Programmable Temperature Test

Programmable Temperature Test

  • How to Change the Refrigerant Oil of Thermal Shock Test Chamber? How to Change the Refrigerant Oil of Thermal Shock Test Chamber?
    Dec 28, 2024
    How to Change the Refrigerant Oil of Thermal Shock Test Chamber? Thermal shock test chamber is a necessary test equipment for metal, plastic, rubber, electronics and other material industries, used to test material structure or composite materials, in an instant under the continuous environment of extremely high temperature and extremely low temperature to endure the degree of chemical changes or physical damage caused by thermal expansion and contraction of the sample in the shortest time. Thermal shock test chamberr meets the test method: GB/T2423.1.2, GB/T10592-2008, GJB150.3 thermal shock test. In thermal shock test chamber, if the compressor is semi-closed piston compressor in operation for 500 hours, it is necessary to observe the oil temperature and oil pressure changes of the frozen oil, and if the frozen oil is discolored, it must be replaced. After the initial operation of the compressor unit for 2000 hours, the cumulative operation of three years or the operation time of more than 10,000 to 12,000 hours should be maintained within a time limit and the chilled oil should be replaced. The refrigerated oil replacement of the semi-closed piston compressor in thermal shock test chamber can be performed according to the following steps: 1, Close high pressure exhaust and low pressure suction stop valve of thermal shock test chamber, and then screw down the oil plug, the oil plug is generally in the bottom of the crankcase, and then put the frozen oil clean and clean the filter. 2, Use the low-pressure impact gas valve needle to blow nitrogen into the oil port and then use the pressure to discharge the residual oil in the body, install a clean filter and tighten the oil plug. 3. Connect the low pressure tube filled with fluorine gauge to the low pressure process valve needle with a vacuum pump to pump the crankcase into negative pressure, and then remove the other fluorine tube separately, put one end into the chilled oil, and put the other end on the valve needle of the low pressure suction of the oil pump. The chilled oil is sucked into the crankcase due to the negative pressure, and add it to the position slightly higher than the lower limit of the oil mirror line. 4. After injection, tighten the process column or remove the fluorine filling tube, and then connect the fluorine pressure gauge to vacuum the compressor. 5. After vacuuming, it is necessary to open the high and low pressure stop valve of the compressor to check whether the refrigerant has leaked. 6, Open thermal shock test chamber unit to check the lubrication of the compressor and the oil level of the oil mirror, the oil level can not be less than a quarter of the mirror. The above is how to replace the refrigerant oil of the semi-closed piston compressor in thermal shock test chamber. Because the refrigerant oil has hygroscope, the replacement process needs to reduce the air entering the system and the oil storage container. If the cold aging oil is injected too much, there is the risk of liquid shock.
    Read More

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
submit

home

products

WhatsApp

contact us