banner
Home

Manufacturing High Quality Forced Test Chamber

Manufacturing High Quality Forced Test Chamber

  • Influence of Capillary Length of High and Low Temperature Test Chamber on Parameters of Refrigeration System Influence of Capillary Length of High and Low Temperature Test Chamber on Parameters of Refrigeration System
    Jan 09, 2025
    Influence of Capillary Length of High and Low Temperature Test Chamber on Parameters of Refrigeration System 1. Influence on suction and exhaust temperature and pressure With the same charge amount, the shorter the capillary, the larger the refrigerant flow rate, so the suction temperature and exhaust temperature will decrease; Similarly, when the capillary is constant, the larger the charge amount is, the larger the refrigerant flow rate is, and the suction temperature and exhaust temperature also decrease. However, with the increase of flow, the inspiratory pressure also rises. For the exhaust pressure, the shorter the capillary is, the smaller the filling amount is. When the capillary length is constant, the higher the charge amount is, the higher it is. 2. Influence on condensing temperature and pressure When the refrigerant charge is constant, the shorter the capillary tube is, the condensation temperature and pressure decrease. When the capillary length is constant, the higher the charge amount, the higher the condensing temperature and pressure. 3. Influence on evaporation temperature and pressure The shorter the capillary, the greater the evaporation temperature and pressure. When the capillary length is constant, the higher the charge amount, the higher the evaporation temperature and pressure. 4. the influence of supercooling and superheat When the refrigerant charge is constant, the longer the capillary is, the higher the supercooling degree and the superheat degree are. When the capillary length is constant, the higher the charge amount, the greater the supercooling degree and the smaller the superheat degree. 5. Influence on cooling capacity, power consumption and performance coefficient EER When the refrigerant charge is constant, the longer the capillary length, the smaller the power consumption, but the cooling capacity is also smaller, the EER is smaller. When the charge amount increases to a certain extent, because of the influence of heat exchange temperature difference, the cooling capacity increases, and the EER also increases. 6. Design points of capillary system (1) On the high pressure side, the reservoir is generally not used, in fact, whether the reservoir is used does not depend on what kind of throttling device, but depends on whether the operation of the entire system is needed, such as heat pump system, shutdown pump system. (2) In the suction tube, it is best to use a gas-liquid separator. Because when the capillary system is shut down, the high and low pressure side will balance and the evaporator will accumulate refrigerant liquid, the gas-liquid separator can prevent liquid shock and refrigerant migration. (3) The high pressure side can accommodate all the refrigerant charged, which is to prevent the capillary blockage when the damage to the high pressure piping system and compressor. (4) In the high load condition of the evaporator, because the capillary system can be fed back to the condenser side, the condenser should take into account whether the condensing pressure will be too high under this condition, so it is necessary to increase the condensing heat transfer area. (5) The pipe between the condenser outlet and the capillary inlet should not accumulate refrigerant liquid. One is that when the compressor is shut down, this part of the refrigerant liquid will evaporate because of the pressure drop, flow into the evaporator and condense, thus bringing some heat to the refrigeration space, which may have an impact on the closed space of the refrigerator, for the air conditioning, this part of the heat can be ignored; Another is that this will delay the time of the balance of the high and low voltage side, which may cause problems when the low torque compressor starts again, which can generally be solved by increasing the delay in the control (in fact, this is also good for reducing the impact of the starting current on other electrical appliances or the grid). (6) The capillary inlet must be filtered to prevent clogging, especially the HFC refrigerant used now, which is required to add a dryer in design. (7) Before the refrigerant enters the capillary, it is best to have a certain degree of undercooling, which can be added to the evaporator by adding a section of undercooling tube, or generating heat exchange with the suction tube, so that the gas flash in the capillary is minimal, thereby increasing the cooling capacity and ensuring the refrigerant flow. However, it should be noted that at low temperature conditions, the undercooling may be too large because there is a little return liquid in the suction tube, which increases the capillary flow rate, and in turn increases the undercooling degree, which may eventually cause the return liquid.
    Read More
  • Technical Characteristics of Refrigeration and Temperature Control System of High and Low Temperature Test Chamber Technical Characteristics of Refrigeration and Temperature Control System of High and Low Temperature Test Chamber
    Dec 30, 2024
    Technical Characteristics of Refrigeration and Temperature Control System of High and Low Temperature Test Chamber High and low temperature test chamber is a kind of test equipment widely used in various industries, which is widely used to simulate various environmental conditions and test the durability, reliability and corrosion resistance of products. The technical characteristics of the high and low temperature test chamber are mainly reflected in its refrigeration system and temperature control system. First of all, the refrigeration system of the high and low temperature test chamber has a high refrigeration capacity and refrigeration speed. During the temperature control process, a refrigeration system is needed to quickly reduce the temperature inside the test chamber. At present, the mainstream refrigeration system mainly has two kinds of compression refrigeration system and refrigerant loop circulation system. Among them, the compression refrigeration system has a high refrigeration capacity and refrigeration speed, which can quickly reduce the temperature inside the test chamber to the set temperature, but also to ensure the stability of the temperature. Secondly, the temperature control system of the high and low temperature test chamber has high accuracy and stability. The temperature control system is the core part of the whole test chamber, which realizes the accurate control and stability maintenance of the internal temperature of the test chamber through the adjustment and control of the refrigeration system and the heating system. The current mainstream temperature control system mainly includes PID control system and intelligent control system. Among them, the PID control system has the characteristics of high precision and high stability, which can realize the accurate control of the temperature inside the test chamber, and is suitable for the test environment with high requirements for temperature control accuracy. The intelligent control system has the characteristics of more intelligent, and can realize the automatic control and adjustment of the internal temperature of the test chamber through self-learning algorithm and big data analysis technology, which is suitable for the occasions with relatively broad test environment requirements. In summary, the technical characteristics of the high and low temperature test chamber are mainly reflected in its refrigeration system and temperature control system. The compression refrigeration system and PID control system have the characteristics of high cooling capacity, high cooling speed, high temperature control accuracy and high stability, which are suitable for the test environment requiring high temperature control accuracy and stability. In the future, with the development of artificial intelligence and Internet of Things technology, the control system of high and low temperature test chamber will continue to develop and improve in the direction of intelligence, automation and remote control, so as to better meet market demand.
    Read More

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
submit

home

products

WhatsApp

contact us