Email Us :
info@labcompanion.cn-
-
Requesting a Call :
+86 18688888286
High and Low Temperature Test Standard for PC Plastic Material
First, high temperature test
After being placed at 80±2°C for 4 hours and at normal temperature for 2 hours, the dimensions, insulation resistance, voltage resistance, key function, and loop resistance should meet normal requirements, and the appearance should not be deformed, warped, or degumming. Key bumps collapsing at high temperatures and reduced pressing force are not evaluated.
Second, low temperature test
After being placed at -30±2℃ for 4 hours and at normal temperature for 2 hours, the dimensions, insulation resistance, voltage resistance, key function, and loop resistance should meet normal requirements, and the appearance should not be deformed, warped, or degumming.
Third, temperature cycling test
After being placed in 70±2℃ for 30 minutes, remove at room temperature for 5 minutes; then after being placed in -20±2℃ for 30 minutes, remove at room temperature for 5 minutes. After such 5 cycles, the dimensions, insulation resistance, voltage resistance, key function, and loop resistance should meet normal requirements, and the appearance should not be deformed, warped, or degumming. Key bumps collapsing at high temperatures and reduced pressing force are not evaluated.
Fourth, heat resistance
After being placed in an environment with a temperature of 40±2℃ and a relative humidity of 93±2%RH for 48 hours, the dimensions, insulation resistance, voltage resistance, key function, and loop resistance should meet normal requirements, and the appearance should not be deformed, warped, or degumming. Key bumps collapsing at high temperatures and reduced pressing force are not evaluated.