banner
Home News

Maintenance Methods for High and Low Temperature Test Chamber

Maintenance Methods for High and Low Temperature Test Chamber

September 21, 2022

Maintenance Methods for High and Low Temperature Test Chamber 

High and low temperature test chamber can simulate the change rule of temperature in the atmospheric environment, it is suitable for product parts and materials in the case of cyclic changes in high temperature and low temperature (alternating), to test the reliability of various performance indicators and commonly used in product design, improvement, identification and inspection and other aspects.

high and low temperature test chamber

In order to ensure the durability and accuracy of the equipment, we need to master the scientific maintenance methods and adhere to mainten equipment in long term. Below by Lab Companion for everyone to explain what you need to pay attention to the maintenance of high and low temperature test chamber.

1, for high and low temperature test chamber, we generally recommend that it will be placed in the temperature of 8 ℃ ~ 28 ℃ in the indoor environment, or the laboratory shall be equipped with appropriate air conditioning or other refrigeration equipment if  it can not meet the above conditions.

2, specialized professional management and maintenance, qualified enterprises should send special personnel to the supplier's factory for training from time to time, in order to obtain a more professional maintenance experience and ability.

3, make sure to clean the condenser every 3 months. If the compressor is air-cooled, the condensing fan should be regularly repaired and the condenser should be decontaminated to ensure good ventilation and heat dissipation. If the compressor is water-cooled, it is not only necessary to ensure its inlet pressure and inlet temperature, but also to ensure the corresponding flow rate, and regularly clean the inside of the condenser to ensure its continuous heat dissipation.

4, regular cleaning evaporator, due to the cleanliness of the test product is different, under the action of forced wind circulation evaporator will condense a lot of dust and other small particles, so it should be cleaned regularly.

5, clean the waterway and humidifier, if the waterway is not smooth, the scale of the humidifier is easy to lead to dry burning of the humidifier, which may damage the humidifier, so the waterway and humidifier must be regularly cleaned.

6, after each test is completed, the temperature is set to the same as the ambient temperature of the test site, and then cut off the power after about 30 minutes of work, and wipe the inner wall of the studio.

7, the product should be regularly switched on every half month if lt is not used in long turn, and the power time should not less than 1 hour.

Regular scientific and reasonable maintenance of the high and low temperature test chamber can not only maximize the service life of the high and low temperature test chamber, but also effectively avoid equipment failure caused by idle maintenance.

If you want to know more about the maintenance of environmental test chambers, you can contact us, Lab Companion will provide you with professional consulting services.

Contact information

Lab Companion LTD

Address: Changcheng Juyi,Industrial Park of Tutang.Changping Town,Dongguan CityGuangdong,China

Mobile: 186 8888 8286 (wechat number is same)

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
submit

home

products

WhatsApp

contact us