Daily maintenance tips for high and low temperature test chambers and alternating high and low temperature test chambers

Daily maintenance tips for high and low temperature test chambers and alternating high and low temperature test chambers

October 09, 2024

Daily maintenance tips for high and low temperature test chambers and alternating high and low temperature test chambers

1. High and low temperature test chambers are generally relatively high, and we recommend placing them in a relatively benign temperature environment. Our experience temperature value is 8 ℃~23 ℃. For laboratories that do not have this condition, appropriate air conditioners or cooling towers must be equipped.

2. It is necessary to adhere to professional management by dedicated personnel. Units with conditions should periodically send dedicated personnel to the supplier's factory for training and learning, in order to gain more professional experience and ability in maintenance and repair Hongzhan Instrument.

3. Regularly clean the condenser every 3 months: For compressors that use air-cooled cooling, the condenser fan should be regularly inspected and the condenser should be cleaned and dusted to ensure good ventilation and heat transfer performance; For compressors that use water-cooled cooling, in addition to ensuring their inlet water pressure and temperature, it is also necessary to ensure the corresponding flow rate. Regular cleaning and descaling of the condenser interior is also necessary to obtain its continuous heat transfer performance.

4. Regularly clean the evaporator: Due to the different cleanliness levels of the test samples, a lot of small particles such as dust will accumulate on the evaporator under forced air circulation, and should be cleaned regularly.

5. Cleaning and balancing of circulating air blades and condenser fans: Similar to cleaning evaporators, due to the different working environments of the test chamber, many small particles such as dust may accumulate on the circulating air blades and condenser fans, and should be cleaned regularly.

6. Cleaning of waterway and humidifier: If the waterway is not smooth and the humidifier scales, it is easy for the humidifier to dry and burn, which may damage the humidifier. Therefore, it is necessary to regularly clean the waterway and humidifier.

7. After each experiment, set the temperature near the ambient temperature, work for about 30 minutes, then cut off the power and clean the inner wall of the workshop.

If the equipment needs to be relocated, it is best to do so under the guidance of technical personnel from Hongzhan Company to avoid unnecessary damage or damage to the equipment.

When the product is not in use for a long period of time, it should be powered on regularly every half month, and the power on time should not be less than 1 hour.

10. Maintenance principle:

Due to the fact that high and low temperature test chambers are mainly composed of electrical, refrigeration, and mechanical systems, once there is a problem with the equipment, a comprehensive inspection and analysis of the entire equipment system should be carried out.

Generally speaking, the process of analysis and judgment can start with "external" and then "internal", that is, after excluding external factors, the equipment can be systematically decomposed based on the fault phenomenon. Then, the system can be comprehensively analyzed and judged. Alternatively, the reverse reasoning method can be used to find the cause of the fault: first, check whether there is a problem with the electrical system according to the electrical wiring diagram, and finally check whether there is a problem with the refrigeration system. Before understanding the cause of the fault, it is not advisable to disassemble or replace components blindly to avoid unnecessary trouble.